Capacitor
Radial Standard Aluminum Electrolytic Capacitor 105C
Key Specifications/Special Features:
Operating temperature:
-40 to +105 degrees Celsius (6.3 to 100V)
-25 to +105 degrees Celsius (160 to 450V)
Rated voltage: 50V
Nominal capacitance: 1uf~47uf
Capacitance tolerance: <=20% (20 degrees Celsius, 120Hz)
Leakage current: UR: <=100V
I: <=0.01 CR UR (uA) or 3&cupA (whichever is greater) two minutes
After UR <=160V: I <=0.03 CR UR +10 (&cupA) two minutes after
Dissipation factor (25 degrees Celsius, 120Hz):
UR: 6.3, 10, 16, 25, 35, 50, 63, 100, 160 to 250 and 350 to 450V
Tgd: 0.22, 0.19, 0.16, 0.14, 0.12, 0.10, 0.09, 0.08, 0.15 and 0.20
Over 1, 000uF, 0.02 is added to every 1, 000uF increase
Load life: After applied rated voltage for 1, 000 hours at +105 degrees Celsius, at
C <=+-25% of initial
Value, tgd <=200% of specified value, IL<=specified value
Shelf life: After shelf for 500 hours (without voltage applied) at +105 degrees Celsius,
Then restored for 24 hours at room
Temperature: At C <=+-25% of initial value, tgd <=200% of specified value, IL<= specified
Features:
Wide temperature range: -40 to +105 degrees Celsius
Voltage range: 50V
Stable and reliable performances
Suitable for use in electronic circuits for coupling, decoupling bypass and filtering
Items |
Characteristics |
Capacitance Tolerance |
±20% (120Hz, 20ºC) |
Operating temperature Range |
-55~+105ºC |
-40~+105ºC |
-25~+105ºC |
Rated Voltage Range |
6.3~100V |
160~400V |
450V |
Leakage Current |
WV <= 100V, I <= 0.01CV or 3uA(After 2 minutes application of DC working voltage, at 20ºC) |
WV > 100V, I <= 0.03CV+20 (uA) (After 5 minutes application of DC working voltage, at 20ºC) |
Dissipation Factor(tan δ) |
Measurement Frequency: 120Hz. Temperature: 20ºC |
Rated Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63 |
100 |
160~250 |
350 |
400~450 |
tan δ (MAX) |
0.20 |
0.17 |
0.16 |
0.14 |
0.12 |
0.10 |
0.08 |
0.08 |
0.15 |
0.20 |
0.25 |
When nominal capacitance exceeds 1000uF, add 0.02 to the value above for each 1000uF increase. (20ºC,120Hz) |
Low Temperature Stability |
Measurement Frequency: 120Hz. |
Rated Voltage (V) |
6.3 |
10 |
16 |
25 |
35 |
50 |
63~100 |
160~250 |
350,400 |
450 |
Impedance Ratio (MAX) |
Z (-25ºC) / Z (20ºC) |
4 |
3 |
2 |
2 |
2 |
2 |
2 |
3 |
6 |
15 |
Z (-40ºC) / Z (20ºC) |
__ |
__ |
__ |
__ |
__ |
3 |
3 |
4 |
10 |
__ |
Z (-55ºC) / Z (20ºC) |
8 |
6 |
4 |
3 |
3 |
3 |
__ |
__ |
__ |
__ |
Load Life |
3000 hours, with application of working voltage at 105ºC. |
Capacitance Change |
Within ± 20% of Initial Value |
tan δ |
200% or less of Initial Specified Value |
Leakage Current |
Initial Specified Value or less |
Shelf Life |
1000hours, no voltage applied, at 105ºC. After Test:UR to be applied for 30 minutes, 24 to 48 hours before measurement. |
Capacitance Change |
Within ± 20% of Initial Value |
tan δ |
150% or less of Initial Specified Value |
Leakage Current |
Initial Specified Value or less |
Standards |
JIS C 5141 and JIS C 5102 |